FREE
AKTU Power Systems Faults Analysis & Protection Lab (BEEZ751) Syllabus PDF – B.Tech 4th Year
Power Systems Faults Analysis & Protection Lab BEEZ751
All syllabus, notes, question bank & PYQ for this subject
Free
Download now
- English
- Semester 7
- 0 downloads
- 0 views
Official AKTU syllabus of Power Systems Faults Analysis & Protection Lab (BEEZ751) for B.Tech 4th Year – 1 credits, L-T-P 0-0-2. Read the unit-wise course content, course outcomes, evaluation pattern and recommended books online, or download the PDF.
Syllabus — Power Systems Faults Analysis & Protection Lab
Download PDFBEEZ751 · 1 credits · L-T-P 0-0-2
Pre-requisites of course: Power System-I Lab
Course Outcomes
Upon completion of the course, the student will be able to:
| CO1 | Test relays for various characteristics and compare results with the performance characteristics provided by manufacturers. | K4 |
| CO2 | Apply Newton-Raphson and Gauss-Seidel methods to solve power flow problems. | K3 |
| CO3 | Analyze types of short-circuit faults in power systems. | K4 |
| CO4 | Demonstrate different numerical integration methods and factors influencing transient stability | K3 |
| CO5 | Analyze power system components, focusing on insulation properties and alternator sync requirements. | K4 |
Note: - Minimum 10 experiments are to be performed from the following list: (A) Hardware-Based Experiments:
- To determine fault current for L-G, L-L, L-L-G and L-L-L faults at the terminals of an alternator at very low excitation.
- To study the over-current relay and the effect of PSM and TSM.
- To study the percentage differential relay.
- To study Impedance, MHO and Reactance type distance relays and zones of protection.
- To study the Ferranti effect of a transmission line/cable.
- To measure the dielectric Strength of transformer oil.
- To study the Synchronization of the alternator with an infinite bus bar.
- To determine the positive sequence, negative sequence and zero sequence reactance of an alternator.
- To study the effect of different shapes of electrodes on dielectric (air) breakdown.
- To study the gas-actuated Buchholz relay for oil-filled transformer.
- To determine the sub-transient (xd″), transient (xd′) and steady state reactance (xd) of a synchronous machine. * The available Experiments from above list may be performed on virtual lab on following virtual lab link: http://vlab.co.in/ (B) Simulation-Based Experiments (using Scilab/MATLAB or any other equivalent open-source software platform)
- To obtain formation of Y-bus.
- Perform load flow analysis on a 3- Bus System using G-S Method.
- Perform load flow analysis on a 3- Bus System using N-R Method.
- To perform symmetrical fault analysis in a power system.
- To perform unsymmetrical fault analysis in a power system.
- Swing Curve by Step-by-Step Method.
- Determination of the stability of a SMIB system in occurrence of a fault by solving the Swing equation by Euler’s Method. Text Books: -
- Haadi Sadat, “Power System Analysis” Tata McGraw Hill.
- T.K. Nagsarskar & M.S. Sukhija, Power System Analysis’ Oxford University Press.
- K. Umarao, “Computer Techniques and Models in Power System”, Wiley DEPARTMENT ELECTIVE – IV [L T P: 3 0 0]